ALT-D
Dehumidifiers
Portable units, with or without a pump, to complete your indoor comfort offering under your brand.
Indoor comfort · Humidity management

DETAILS MAKE THE DIFFERENCE
Every model. In detail.
Documentary basis: catalogue dated February 28, 2026; technical review dated September 18, 2026. Catalogue values are indicative.
ALT-D35
- Drain pump
- No
- Commercial class (US pints/day)
- 35
- Removal at 65°F / 60% RH (US pints/day)
- 36.53
- IEF at 65°F / 60% RH (L/kWh)
- 2.01
- Rated input (W)
- 670
- Rated current (A)
- 5.90
- High / medium airflow (CFM)
- 156 / 123
- High / medium noise (dB(A))
- 45 / 43
- Dimensions (mm)
- 375 × 514 × 240
- Net weight (kg)
- 15.6
ALT-D35P
- Drain pump
- Yes
- Commercial class (US pints/day)
- 35
- Removal at 65°F / 60% RH (US pints/day)
- 36.53
- IEF at 65°F / 60% RH (L/kWh)
- 2.01
- Rated input (W)
- 670
- Rated current (A)
- 5.90
- High / medium airflow (CFM)
- 156 / 123
- High / medium noise (dB(A))
- 45 / 43
- Dimensions (mm)
- 375 × 514 × 240
- Net weight (kg)
- 16.0
ALT-D50
- Drain pump
- No
- Commercial class (US pints/day)
- 50
- Removal at 65°F / 60% RH (US pints/day)
- 49.5
- IEF at 65°F / 60% RH (L/kWh)
- 2.01
- Rated input (W)
- 850
- Rated current (A)
- 7.50
- High / medium airflow (CFM)
- 218 / 176
- High / medium noise (dB(A))
- 48 / 46
- Dimensions (mm)
- 385 × 600 × 240
- Net weight (kg)
- 18.9
ALT-D50P
- Drain pump
- Yes
- Commercial class (US pints/day)
- 50
- Removal at 65°F / 60% RH (US pints/day)
- 49.5
- IEF at 65°F / 60% RH (L/kWh)
- 2.01
- Rated input (W)
- 850
- Rated current (A)
- 7.50
- High / medium airflow (CFM)
- 218 / 176
- High / medium noise (dB(A))
- 48 / 46
- Dimensions (mm)
- 385 × 600 × 240
- Net weight (kg)
- 19.3
35 / 50 are commercial classes, not exact measured values. Compare moisture removal at the same temperature and humidity.
Compare all models
| Specification | ALT-D35 | ALT-D35P | ALT-D50 | ALT-D50P |
|---|---|---|---|---|
| Drain pump | No | Yes | No | Yes |
| Commercial class (US pints/day) | 35 | 35 | 50 | 50 |
| Removal at 65°F / 60% RH (US pints/day) | 36.53 | 36.53 | 49.5 | 49.5 |
| IEF at 65°F / 60% RH (L/kWh) | 2.01 | 2.01 | 2.01 | 2.01 |
| Rated input (W) | 670 | 670 | 850 | 850 |
| Rated current (A) | 5.90 | 5.90 | 7.50 | 7.50 |
| High / medium airflow (CFM) | 156 / 123 | 156 / 123 | 218 / 176 | 218 / 176 |
| High / medium noise (dB(A)) | 45 / 43 | 45 / 43 | 48 / 46 | 48 / 46 |
| Dimensions (mm) | 375 × 514 × 240 | 375 × 514 × 240 | 385 × 600 × 240 | 385 × 600 × 240 |
| Net weight (kg) | 15.6 | 16.0 | 18.9 | 19.3 |
Understanding the data
ALT references are commercial labels, not certified identifiers. Matched systems, voltage, circuit protection, manuals and Canadian status are validated before ordering.
SEER2: seasonal cooling efficiency. EER2: efficiency at a test point. HSPF2: seasonal heating efficiency. IEF: litres of water removed per kWh. Test conditions and matched systems must correspond.
Documents for your configuration.
Request the data sheets, manuals and evidence applicable to the selected matched system. Documents are confirmed for each project; this page is not installation approval.
Explore resourcesYOUR PROJECT
Let’s define your needs.
ALT commercial references. The exact matched system, applicable documentation, availability and terms are confirmed before ordering.