BUILDING TECHNOLOGY & SUPPLY

The essentials to
build further.

HVAC products for your brand. Building technology for your projects. ALTROVIA supports professionals across Canada.

Let’s discuss your projectExplore HVAC products & OEM
Architectural montage inspired by Montréal™
From systems to details.A COMPLETE PERSPECTIVE.
Montréal, Québec · AI-assisted illustration, not an ALTROVIA project.
01Direct manufacturer access
02Project support
03A Canadian perspective

OUR SECTORS

Sectors to explore. A shared vision.

Explore our HVAC families and private-label OEM support. We are also developing complementary building supply categories.

01 / HVAC · PRODUCTS & OEM

Comfort. In every space.

Heat pumps, central systems and dehumidifiers. Explore the ALTROVIA range and build your offering under your own brand.

ALT concept: wall-mounted unit in a contemporary interior
ALT-MSimply comfortable.
Wall-mounted heat pumps · ALT · Concept image

ALT-M

Wall-mounted heat pumps

A ductless system for residential spaces, renovations and your next private-label range.

12K / 18K / 24KDuctless
Discuss this family
Models and specifications

DETAILS MAKE THE DIFFERENCE

Every model. In detail.

Documentary basis: catalogue dated February 28, 2026; technical review dated September 18, 2026. Catalogue values are indicative. Ratings for documented matched systems come from archived June–July 2026 records. Current status and OEM mapping require confirmation.

ALT-M12
Cooling at 95°F (BTU/h)
12,000
Heating at 47°F (BTU/h)
12,500
SEER2
25
EER2
12.8
HSPF2 · Region IV
9.4
Maximum indoor airflow · catalogue (CFM)
424
Maximum indoor sound pressure (dB(A))
40
Indoor dimensions (in)
33.46 × 11.46 × 7.99
Indoor net / gross weight (lb)
22 / 27.5
Outdoor sound pressure (dB(A))
53
Outdoor dimensions (in)
32.68 × 21.26 × 12.8
ALT-M18
Cooling at 95°F (BTU/h)
18,000
Heating at 47°F (BTU/h)
18,500
SEER2
21
EER2
12.8
HSPF2 · Region IV
9
Maximum indoor airflow · catalogue (CFM)
529
Maximum indoor sound pressure (dB(A))
47
Indoor dimensions (in)
To validate
Indoor net / gross weight (lb)
28.6 / 36.3
Outdoor sound pressure (dB(A))
55
Outdoor dimensions (in)
35.04 × 23.54 × 14.65
ALT-M24
Cooling at 95°F (BTU/h)
22,000
Heating at 47°F (BTU/h)
24,000
SEER2
23
EER2
12.8
HSPF2 · Region IV
9.8
Maximum indoor airflow · catalogue (CFM)
824
Maximum indoor sound pressure (dB(A))
48
Indoor dimensions (in)
42.56 × 12.87 × 9.76
Indoor net / gross weight (lb)
35.2 / 41.8
Outdoor sound pressure (dB(A))
58
Outdoor dimensions (in)
37.8 × 27.56 × 15.59

18K indoor dimensions require validation. Other dimensions retain the source-table order; confirm drawings and clearances before installation.

Compare all models
Documented values by commercial reference
SpecificationALT-M12ALT-M18ALT-M24
Cooling at 95°F (BTU/h)12,00018,00022,000
Heating at 47°F (BTU/h)12,50018,50024,000
SEER2252123
EER212.812.812.8
HSPF2 · Region IV9.499.8
Maximum indoor airflow · catalogue (CFM)424529824
Maximum indoor sound pressure (dB(A))404748
Indoor dimensions (in)33.46 × 11.46 × 7.99To validate42.56 × 12.87 × 9.76
Indoor net / gross weight (lb)22 / 27.528.6 / 36.335.2 / 41.8
Outdoor sound pressure (dB(A))535558
Outdoor dimensions (in)32.68 × 21.26 × 12.835.04 × 23.54 × 14.6537.8 × 27.56 × 15.59
Understanding the data

ALT references are commercial labels, not certified identifiers. Matched systems, voltage, circuit protection, manuals and Canadian status are validated before ordering.

SEER2: seasonal cooling efficiency. EER2: efficiency at a test point. HSPF2: seasonal heating efficiency. IEF: litres of water removed per kWh. Test conditions and matched systems must correspond.

Central heat pumps · ALT · Concept image

ALT-C

Central heat pumps

An outdoor unit and air handler for central air distribution. A range configured around your building.

24K / 36K / 48K / 60KDucted
Discuss this family
Models and specifications

DETAILS MAKE THE DIFFERENCE

Every model. In detail.

Documentary basis: catalogue dated February 28, 2026; technical review dated September 18, 2026. Catalogue values are indicative. Ratings for documented matched systems come from archived June–July 2026 records. Current status and OEM mapping require confirmation.

ALT-C24
Cooling at 95°F (BTU/h)
24,000
Heating at 47°F (BTU/h)
24,000
SEER2
21
EER2
13
HSPF2 · Region IV¹
11
Indoor airflow · catalogue (CFM)
820
Indoor noise · catalogue (dB(A))
34-42
Indoor dimensions (mm)
503 × 562 × 1162
Indoor net / gross weight (kg)
64 / 74
Outdoor noise · catalogue (dB(A))
57
Outdoor dimensions (mm)
990 × 426 × 790
ALT-C36
Cooling at 95°F (BTU/h)
34,200
Heating at 47°F (BTU/h)
35,000
SEER2
20.2
EER2
11.5
HSPF2 · Region IV¹
10.2
Indoor airflow · catalogue (CFM)
1,150
Indoor noise · catalogue (dB(A))
38-48
Indoor dimensions (mm)
503 × 562 × 1162
Indoor net / gross weight (kg)
64 / 74
Outdoor noise · catalogue (dB(A))
57
Outdoor dimensions (mm)
990 × 426 × 790
ALT-C48
Cooling at 95°F (BTU/h)
48,000
Heating at 47°F (BTU/h)
48,000
SEER2
20
EER2
12
HSPF2 · Region IV¹
11
Indoor airflow · catalogue (CFM)
1,580
Indoor noise · catalogue (dB(A))
41-53
Indoor dimensions (mm)
563 × 622 × 1352
Indoor net / gross weight (kg)
80 / 90
Outdoor noise · catalogue (dB(A))
59
Outdoor dimensions (mm)
1024 × 396 × 1002
ALT-C60
Cooling at 95°F (BTU/h)
52,500
Heating at 47°F (BTU/h)
54,000
SEER2
19.6
EER2
11.5
HSPF2 · Region IV¹
10.8
Indoor airflow · catalogue (CFM)
2,000
Indoor noise · catalogue (dB(A))
46-57
Indoor dimensions (mm)
563 × 622 × 1352
Indoor net / gross weight (kg)
80 / 90
Outdoor noise · catalogue (dB(A))
59
Outdoor dimensions (mm)
1024 × 396 × 1002

¹ 36K: catalogue values only; certification and HSPF2 region require confirmation. Catalogue airflow is not certification test airflow.

Compare all models
Documented values by commercial reference
SpecificationALT-C24ALT-C36ALT-C48ALT-C60
Cooling at 95°F (BTU/h)24,00034,20048,00052,500
Heating at 47°F (BTU/h)24,00035,00048,00054,000
SEER22120.22019.6
EER21311.51211.5
HSPF2 · Region IV¹1110.21110.8
Indoor airflow · catalogue (CFM)8201,1501,5802,000
Indoor noise · catalogue (dB(A))34-4238-4841-5346-57
Indoor dimensions (mm)503 × 562 × 1162503 × 562 × 1162563 × 622 × 1352563 × 622 × 1352
Indoor net / gross weight (kg)64 / 7464 / 7480 / 9080 / 90
Outdoor noise · catalogue (dB(A))57575959
Outdoor dimensions (mm)990 × 426 × 790990 × 426 × 7901024 × 396 × 10021024 × 396 × 1002
Understanding the data

ALT references are commercial labels, not certified identifiers. Matched systems, voltage, circuit protection, manuals and Canadian status are validated before ordering.

SEER2: seasonal cooling efficiency. EER2: efficiency at a test point. HSPF2: seasonal heating efficiency. IEF: litres of water removed per kWh. Test conditions and matched systems must correspond.

Multi-zone systems · ALT · Concept image

ALT-MZ

Multi-zone systems

Explore catalogue configurations for multiple rooms. Matched combinations and Canadian availability are reviewed for each project.

Project reviewMultiple zones
Discuss this family
Models and specifications

DETAILS MAKE THE DIFFERENCE

Every model. In detail.

Documentary basis: catalogue dated February 28, 2026; technical review dated September 18, 2026. Catalogue values are indicative.

ALT-MZ18
Published cooling (BTU/h)
16,000
Published heating (BTU/h)
18,000
SEER2 · catalogue
22
HSPF2 · region to confirm
10
Maximum indoor units · catalogue
2
Outdoor airflow (CFM)
1,294
Sound pressure (dB(A))
58
Outdoor dimensions (in)
37.80 × 15.59 × 27.56
Net weight (kg)
52
ALT-MZ27
Published cooling (BTU/h)
27,000
Published heating (BTU/h)
27,000
SEER2 · catalogue
22
HSPF2 · region to confirm
10
Maximum indoor units · catalogue
3
Outdoor airflow (CFM)
1,882
Sound pressure (dB(A))
58
Outdoor dimensions (in)
38.98 × 16.77 × 31.10
Net weight (kg)
64
ALT-MZ36
Published cooling (BTU/h)
36,000
Published heating (BTU/h)
36,000
SEER2 · catalogue
20
HSPF2 · region to confirm
10
Maximum indoor units · catalogue
4
Outdoor airflow (CFM)
2,059
Sound pressure (dB(A))
60
Outdoor dimensions (in)
38.98 × 16.77 × 31.10
Net weight (kg)
66
ALT-MZ42
Published cooling (BTU/h)
42,000
Published heating (BTU/h)
45,000
SEER2 · catalogue
22
HSPF2 · region to confirm
11.5
Maximum indoor units · catalogue
4
Outdoor airflow (CFM)
2,647
Sound pressure (dB(A))
57
Outdoor dimensions (in)
40.31 × 15.59 × 39.45
Net weight (kg)
97
ALT-MZ48
Published cooling (BTU/h)
48,000
Published heating (BTU/h)
50,000
SEER2 · catalogue
20
HSPF2 · region to confirm
11
Maximum indoor units · catalogue
4
Outdoor airflow (CFM)
2,941
Sound pressure (dB(A))
58
Outdoor dimensions (in)
40.31 × 15.59 × 39.45
Net weight (kg)
97

Catalogue reference range, for project review only. No approved Canadian combination or current certification is asserted. Unit count depends on the validated combination.

Compare all models
Documented values by commercial reference
SpecificationALT-MZ18ALT-MZ27ALT-MZ36ALT-MZ42ALT-MZ48
Published cooling (BTU/h)16,00027,00036,00042,00048,000
Published heating (BTU/h)18,00027,00036,00045,00050,000
SEER2 · catalogue2222202220
HSPF2 · region to confirm10101011.511
Maximum indoor units · catalogue23444
Outdoor airflow (CFM)1,2941,8822,0592,6472,941
Sound pressure (dB(A))5858605758
Outdoor dimensions (in)37.80 × 15.59 × 27.5638.98 × 16.77 × 31.1038.98 × 16.77 × 31.1040.31 × 15.59 × 39.4540.31 × 15.59 × 39.45
Net weight (kg)5264669797
Understanding the data

ALT references are commercial labels, not certified identifiers. Matched systems, voltage, circuit protection, manuals and Canadian status are validated before ordering.

SEER2: seasonal cooling efficiency. EER2: efficiency at a test point. HSPF2: seasonal heating efficiency. IEF: litres of water removed per kWh. Test conditions and matched systems must correspond.

Dehumidifiers · ALT · Concept image

ALT-D

Dehumidifiers

Portable units, with or without a pump, to complete your indoor comfort offering under your brand.

35 / 50 US pintsPortable
Discuss this family
Models and specifications

DETAILS MAKE THE DIFFERENCE

Every model. In detail.

Documentary basis: catalogue dated February 28, 2026; technical review dated September 18, 2026. Catalogue values are indicative.

ALT-D35
Drain pump
No
Commercial class (US pints/day)
35
Removal at 65°F / 60% RH (US pints/day)
36.53
IEF at 65°F / 60% RH (L/kWh)
2.01
Rated input (W)
670
Rated current (A)
5.90
High / medium airflow (CFM)
156 / 123
High / medium noise (dB(A))
45 / 43
Dimensions (mm)
375 × 514 × 240
Net weight (kg)
15.6
ALT-D35P
Drain pump
Yes
Commercial class (US pints/day)
35
Removal at 65°F / 60% RH (US pints/day)
36.53
IEF at 65°F / 60% RH (L/kWh)
2.01
Rated input (W)
670
Rated current (A)
5.90
High / medium airflow (CFM)
156 / 123
High / medium noise (dB(A))
45 / 43
Dimensions (mm)
375 × 514 × 240
Net weight (kg)
16.0
ALT-D50
Drain pump
No
Commercial class (US pints/day)
50
Removal at 65°F / 60% RH (US pints/day)
49.5
IEF at 65°F / 60% RH (L/kWh)
2.01
Rated input (W)
850
Rated current (A)
7.50
High / medium airflow (CFM)
218 / 176
High / medium noise (dB(A))
48 / 46
Dimensions (mm)
385 × 600 × 240
Net weight (kg)
18.9
ALT-D50P
Drain pump
Yes
Commercial class (US pints/day)
50
Removal at 65°F / 60% RH (US pints/day)
49.5
IEF at 65°F / 60% RH (L/kWh)
2.01
Rated input (W)
850
Rated current (A)
7.50
High / medium airflow (CFM)
218 / 176
High / medium noise (dB(A))
48 / 46
Dimensions (mm)
385 × 600 × 240
Net weight (kg)
19.3

35 / 50 are commercial classes, not exact measured values. Compare moisture removal at the same temperature and humidity.

Compare all models
Documented values by commercial reference
SpecificationALT-D35ALT-D35PALT-D50ALT-D50P
Drain pumpNoYesNoYes
Commercial class (US pints/day)35355050
Removal at 65°F / 60% RH (US pints/day)36.5336.5349.549.5
IEF at 65°F / 60% RH (L/kWh)2.012.012.012.01
Rated input (W)670670850850
Rated current (A)5.905.907.507.50
High / medium airflow (CFM)156 / 123156 / 123218 / 176218 / 176
High / medium noise (dB(A))45 / 4345 / 4348 / 4648 / 46
Dimensions (mm)375 × 514 × 240375 × 514 × 240385 × 600 × 240385 × 600 × 240
Net weight (kg)15.616.018.919.3
Understanding the data

ALT references are commercial labels, not certified identifiers. Matched systems, voltage, circuit protection, manuals and Canadian status are validated before ordering.

SEER2: seasonal cooling efficiency. EER2: efficiency at a test point. HSPF2: seasonal heating efficiency. IEF: litres of water removed per kWh. Test conditions and matched systems must correspond.

OEM branding montages created with OpenArt, inspired by Montréal and Québec. They do not depict completed installations. Exact configuration, applicable ratings and availability are confirmed by quotation.

ALTROVIA OEM

Your range. Your signature.

Branding, packaging and documentation. Share your market and volumes; we clarify the options and terms.

Describe my project
ALTROVIA OEM — Private-label HVAC

* Required fields

How your information is used

info@altroviainc.com

02

Generators

Power supply and backup needs are among the sectors we are exploring. Share your situation and priorities.

Discuss my power needs
Describe my project
Generators

* Required fields

How your information is used

info@altroviainc.com

03
Insulation panels with mineral textures

Insulation

The building envelope and indoor comfort guide our approach to insulation. Tell us about your needs and project considerations.

Discuss my insulation needs
Describe my project
Insulation

* Required fields

How your information is used

info@altroviainc.com

04

Installation supplies & accessories

We are exploring supplies and accessories for installation work. Your practical needs help guide this selection.

Share my needs
Describe my project
Installation supplies & accessories

* Required fields

How your information is used

info@altroviainc.com

05
Interior door and brass handle

Interior doors

Doors and interior finishes are part of our approach to building projects. Let’s discuss the intended use and style.

Discuss the possibilities
Describe my project
Interior doors

* Required fields

How your information is used

info@altroviainc.com

Visuals illustrate product families and branding possibilities. Configuration, availability and terms are confirmed by quotation. Other sectors remain in development.

Every project has a starting point.

Developers

Share the building type, location and main project stages.

Talk with us

Contractors and installers

Describe your practical needs and the constraints to consider.

Talk with us

Resellers and partners

Introduce your business, territory and partnership interests.

Talk with us

ALTROVIA CANADA

Your vision.
Our commitment.

Architectural montage inspired by Montréal

Direct access to manufacturers. A partner by your side.

ALTROVIA is building relationships with manufacturers and building professionals to develop an offering suited to Canadian projects.

Our approach starts with your needs: understand the project, explore possibilities and clarify next steps with the relevant partners.

Our ambition: advance building technologies through cleaner, durable solutions that support renewable energy. Energy efficiency, quality and Canadian standards guide our selection.

SERVING CONSTRUCTION PROFESSIONALSFROM COAST TO COAST

Our team

Rabie G.

Managing Partner

Vicky R.

Partner

Guillaume D.

Partner

Lourdes G.

Executive Assistant · Operations

Paul K.

Financial Controller · Accounting

Diana S.

Executive Assistant · Compliance & Orders

Michael G.

Representative

OUR APPROACH

Select with care.

Project relevance, quality of documentation and Canadian market needs guide the development of our offering.

Let’s start with a conversation.

01

Your needs

Share your project, business and area of interest.

02

The possibilities

We discuss possibilities to explore and useful information.

03

Next steps

Potential options and terms are clarified case by case.

A few things to know before contacting us.

Which products can I explore for OEM?

Our HVAC families include wall-mounted heat pumps, central systems, multi-zone and dehumidifiers. The exact selection, branding and terms are reviewed for your project.

Can I contact you at an early project stage?

Yes. A description of your needs, location and approximate timing are enough to start the conversation.

How can I propose a partnership?

Introduce your company and the type of collaboration you have in mind through the reseller form or by email.

News

From Altrovia

All news

LET’S DISCUSS YOUR PROJECT

Your next project starts here.

Have a project, a sourcing need or a partnership proposal? Share the essentials with us.

Email
info@altroviainc.com
Phone
844-660-5482
Tell us about your project* Required fields

How your information is used

info@altroviainc.com